Yes, absolutely! It takes around 10 minutes to fill out the form and makes it easier for the scientist in-charge to schedule your appointment and plan the experiment. Importantly, it saves time as you will be already providing the required information before coming with your samples.
Laser confocal microscopy requires the use of cover glass that is specially designed with an approximate thickness of 0.17 mm. This thickness is important for acquiring high resolution and sharp images. Using thick coverslips will result in soft hazy images due to spherical and chromatic aberrations. This is particularly relevant when using high N.A. objectives at higher magnifications; since the working distance for these high N.A. objectives is very small, thick coverslips take too much of their working distance making it a challenge to focus the sample.
Yes, you are welcome to discuss and trouble-shoot your experiments with the scientist in-charge. The facility is here to support all the users from designing experiments, capturing images and processing data.
It is preferable not to do so but we do understand there could be circumstances beyond one’s control. The decision will be made depending on the availability of the system and at the discretion of the scientist in-charge.
You can learn more about microscopy and its applications from our website and navigating the “Learning Resources” tab. You will find webinar and demo videos from CCRF-AIIMS under “Tutorials” tab and a list of books, links to videos and websites for learning the basics of microscopy under “Other Important Resources” tab. You are welcome to speak to the scientist in-charge of the facility who can help you get started with the basics of microscopy.
Fluorescence imaging is very sensitive to the stability of the fluorophores. Do not panic if this happens! There could be multiple reasons; the sample you prepared could be old or you could have kept it exposed to light at room temperature and bleached it in the process. Every microscope is different and the settings/parameters for visualizing the sample are also not the same. If possible, try to get an image that you have captured previously on another microscope with the acquisition settings. This will be helpful in figuring out if there is any particular issue with your sample or the microscope.
At the heart of the confocal microscope systems are the lasers. These lasers are coherent light sources that are used to excite the fluorophores in your sample. Therefore, without prior knowledge of the excitation/emission wavelengths of the dyes/fluorophores, you cannot decide which lasers to use to excite your samples. You may not know the exact excitation/emission wavelengths but you should be aware of the wavelength range at which the dyes/fluorophores get excited and emit fluorescence.
Every user has different experimental needs. Some users might want to do quantifications/data analyses and making image panels themselves. We are happy to provide all the required support andassistance in terms of offline processing, data quantification and making image panels on a case-to-case basis.
Please write to us at microscopy.ccrf@aiims.edu to discuss/design your experiments or to fix an appointment. You are welcome to walk-in to the facility and talk to the scientist in-charge; alternatively, you can also schedule a virtual meeting via Zoom/Webex/Skype/Google Meet.
Yes, this can be done after discussion with the scientist in-charge. Usually, the preferred time slot is a maximum of 3 continuous hours in a day but depending on the demands of the experiment, arrangements can be made for longer use of the system. Please reach out to the scientist in-charge well ahead of time for better planning and execution of your experiments.
No, you are not allowed to handle the system on your own. You will be allowed to focus your sample and select a region that you want to image. You are free to ask questions and learn the theory behind what is exactly going on during image acquisition. You may be allowed under certain circumstances to handle the system only under supervision of the scientist in-charge at his/her discretion.
Acknowledgement is mandatory for any publications, reports and scientific content resulting from the use of the Confocal, the Airyscan or the Image processing systems in CCRF. This helps us to track how well the system has been utilized for publication purposes. The standard sentence to be used is “We acknowledge the Microscopy and Imaging Facility, CCRF, AIIMS New Delhi for help with image acquisition and analyses.” Please get in touch with the scientist in-charge to get details on the microscope model, details of the objectives, N.A., etc. before writing the Materials and Methods section of your paper.
Authorship in a manuscript is subjective and depends on the effort, time, inputs for the experimental design, troubleshooting, image processing, quantification and statistical analyses including help with writing up specific section(s) of the manuscript that the scientist has contributed to. This should be discussed upfront and depending on how much help is required from the facility/ scientist, a consensus can be reached on whether authorship is warranted.
how much help is required from the facility/ scientist, a consensus can be reached on whether authorship is warranted.
For general authorship guidelines, please refer the following:
National Institutes of Health Guidelines (Schematic)
International Committee of Medical Journal Editors Guidelines
International Committee of Medical Journal Editors Guidelines